

- #Universal database update install
- #Universal database update upgrade
- #Universal database update software
- #Universal database update password
- #Universal database update series
If upgrading from a version prior to 5.x, review Badge Type designs and adjust as needed.After the firmware has been successfully updated, the SCP will reset and begin downloading the system information and cards data resulting in some cards not functioning for up to 5 minutes or so. Readers installed under legacy panels will revert to their offline mode which by default is Facility Code. During this time, any readers installed under an EP/LP/MP will continue to function as normal. For any panel uninstalled, re-install each SCP by editing the SCP, enabling the Device Installed checkbox, and clicking saveĪccess It! will automatically upload any stored transactions and then reset the SCP and download new firmware.Setup the Access It! service to match the old Access It! service.Right Click on the Access It! Universal service.Enter, (or copy/paste), the System ID received upon purchase.Select the Access It! server from the dropdown menu.Select the File tab from the top left of the window.The following steps can now be completed on either the Server or Client machines. Click the Finish button within the Access It! InstallShield form.
#Universal database update install
#Universal database update password
If configured to use ‘This account:’, the exact Username and Password will be needed in the Post Installation.
#Universal database update upgrade
If upgrading from a version prior to 5.x, make note of any custom designed reports as they may need to be adjusted after the upgrade.If upgrading from a version prior to 5.x, make note of Badge Type designs as they may need to be adjusted after the upgrade.The following steps should be completed on the Server machine (computer with license attached).
#Universal database update series
See KB article "LP Series Legacy Mode" for additional details. Once disabled, the LP panel will need to be set back to normal operating mode and changed from an EP to a LP panel within the SCP properties.
#Universal database update software
If utilizing the Access It! API a the upgraded software must utilize HTTPS traffic.Bosch panels should be updated to Bosch GV3 v8.13 or greater. Bosch G, GV2 and GV3 v8.05 intrusion detection panels are no longer supported.Regional Server installations must use the Database Configuration Utility and drop all SQL replication Publications and Subscriptions.See device specific KB articles for configuration information. Legacy Biometric integrations require the biometric type to be redefined within the SCP screen.Due to User Permission enhancements, it may be required that User Group properties be updated.Details on what panels will be disabled can be found in this SCP Automatically Uninstalled article. Any database updates made while uninstalled will be processed after the panel completes the firmware download and reset. While uninstalled, the Access It! service will continue to process all panel events. This is done so that the dealer may install the SCPs one at a time allowing for a controlled system-wide reset. After the upgrade is performed, all SCP panels will be set as Uninstalled.HID pivCLASS 5.21 (or newer) is required on version 9.0.Legacy GetRecordSet COM call is not supported due to 64-bit incompatibility.Legacy barfont.dll is not supported due to 64-bit incompatibility.Legacy biometrics is not supported due to 64-bit incompatibility.Legacy 2G Hardware using the 2G protocol is not supported due to 64-bit incompatibility.The upgrade process requires that a backup of the Access It! databases be performed prior to any upgrade. This document outlines the steps needed to upgrade an existing Access It! system to an Access It! v7 system. This article pertains to a version of software no longer supported by ACRE.
